| Power switch |
| |
The supply can be operated in
a stand-alone mode by turning on an A/C power switch or as a
slave to another Cresnet system in the PWR OFF/SLAVE position.
In slave mode, 24V from the Cresnet connector closes a relay
that provides A/C for the supply. |
| Output |
| |
Each of the 8 outputs has a
75W rating with a combined output rating of 300 watts. Each
output has an electronic circuit breaker that disables a faulted
output without affecting the others. The circuit breaker can
be reset by either pressing a reset button or by Cresnet command.
The total current in the supply is monitored and all breakers
are tripped if the overall rating is exceeded. All faults can
be reported to Cresnet. There are two 2-position large phoenix
connectors for each output. |
| Cresnet |
| |
4-Pin screw terminal |
| LEDs |
| |
PWR |
Green - indicates 24V supply
is on |
| |
NET |
Yellow - indicates device is
polled in Cresnet. |
| |
SETUP |
Red - Used for future plug and
play |
| |
8 PWR |
Green - Indicates that output
has power |
| |
8 OVRLD |
RED - Indicates that electronic
breaker has tripped. |
| Pushbuttons |
| |
8 overload reset buttons; 1
Cresnet setup button |
| Environmental |
| |
Operating temperature |
5 to 40 deg C |
| |
Humidity |